- Home Page /
- Tools & Home Improvement /
- Building Supplies /
- HVAC /
- Heaters & Accessories /
- Supplying Demand Q108 HN67GJ002 Furnace Heat ...
Supplying Demand Q108 HN67GJ002 Furnace Heat Pump Sequencer 1SPDT 24 Volt On 1-25 Off 65-115
NAD 918
Price Details
Excluding Shipping & Custom charges ( Shipping and custom charges will be calculated on checkout )
*All items will import from US
QTY:
Ubuy works hard to protect your security and privacy. Our advanced payment security system ensures confidentiality by encrypting your information during transmission using AES (Advanced Encryption Standards) and SSL (Secure Socket Layer) protocols. Your payment details are 100% secure as we do not share your payment details with third party sellers.
The Supplying Demand Q108 HN67GJ002 Furnace Heat Pump Sequencer is a high-quality replacement part designed to work in different types of furnaces and heat pumps.
Fast
Shipping
Free
Return*
Secure Packaging
100% Original Products
PCI DSS Compliance
ISO 27001 Certified
What Stands Out
Product Details
- 1SPDT 24 Volt Sequencer for Furnace & Heat Pump
- On: 1 - 25 Seconds | Off: 65-115 Seconds
- Compatible with Electric, Gas, & Oil Furnaces
- Five second delay between subsequent stages
- Replacement part compatible with Major Brands
- Supplied in Supplying Demand packaging
| Item Weight | 0.5 lbs (230 grams) |
Who Should Buy?
-
HVAC Technicians
Ideal for technicians needing a reliable sequencer for furnace and heat pump installations and repairs.
-
Homeowners
Homeowners seeking to replace their malfunctioning sequencer to improve HVAC system efficiency and reliability.
-
DIY Enthusiasts
Perfect for DIY enthusiasts wanting to upgrade or fix their home heating systems with an easy component replacement.
-
Professional Installers
Not suitable for installers needing a high-capacity sequencer for large commercial systems or heavy-duty applications.
-
Old Systems
May not be compatible with significantly outdated HVAC systems, requiring updated components for effective operation.
-
Non-Technical Users
Not recommended for users without technical knowledge, as installation may require specific skills and understanding.
Product Description
Supplying Demand Q108 HN67GJ002 Furnace Heat Pump Sequencer 1SPDT 24 Volt On 1-25 Off 65-115
Customer Questions & Answers
-
Question:
What is the purpose of the Supplying Demand Q108 HN67GJ002 Furnace Heat Pump Sequencer?
Answer: The Supplying Demand Q108 HN67GJ002 Furnace Heat Pump Sequencer is designed to control the operation of heating and cooling systems by managing the sequence of various components, such as relays and fans. This sequencer operates on a 24-volt system, facilitating efficient switching between heating and cooling modes. In practice, it ensures that the heat pump’s stage 1 turns on between 1 to 25 degrees and off between 65 to 115 degrees, enhancing temperature control and energy efficiency. -
Question:
How do I install the Supplying Demand Q108 HN67GJ002 sequencer?
Answer: Installation of the Supplying Demand Q108 sequencer involves disconnecting power to your heating system, removing the old sequencer, and replacing it with the new unit following the wiring diagram provided. It’s essential to properly connect the wires to ensure your system operates safely and effectively. Make sure to test the system after installation to confirm that it switches correctly between heating and cooling modes, optimizing comfort in your home. -
Question:
What specifications should I look for in a sequencer like Q108 HN67GJ002?
Answer: When considering the Supplying Demand Q108 HN67GJ002 sequencer, it’s important to note its specifications such as the 1SPDT (Single Pole Double Throw) functionality, 24-volt operation, and control range of 1-25 degrees for on and 65-115 degrees for off. These specs ensure compatibility with most heating and cooling systems, allowing for precise temperature management based on your specific HVAC requirements. -
Question:
What should I do if my furnace isn’t switching on or off correctly?
Answer: If your furnace is not switching on or off as expected, there may be an issue with the sequencer or related components. Start by checking the wiring connections for any loose or broken wires. Inspect the sequencer for signs of wear or damage. If everything appears intact but malfunctions continue, it may be beneficial to consult with a professional HVAC technician for a thorough diagnosis and potential replacement of faulty components such as the Q108 sequencer. -
Question:
Can the Q108 HN67GJ002 sequencer work with any HVAC system?
Answer: The Supplying Demand Q108 HN67GJ002 sequencer is compatible with various HVAC systems that operate on a 24-volt control voltage and require a single pole double throw (1SPDT) switch. However, it's vital to verify your system's specifications before installation to ensure proper compatibility. This ensures that the sequencer effectively manages sequencing for heating and cooling operations in your specific setup. -
Question:
How does the temperature range of the Q108 sequencer affect home comfort?
Answer: The temperature range of the Supplying Demand Q108 HN67GJ002 sequencer plays a crucial role in home comfort. With an 'on' range of 1-25 degrees and an 'off' range of 65-115 degrees, it allows the heat pump to activate under cooler conditions, gradually adjusting your home’s temperature to your desired level. This precise control can lead to more consistent heating and cooling, ensuring that your environment remains comfortable throughout the seasons. -
Question:
What materials is the Q108 HN67GJ002 sequencer made from?
Answer: The Supplying Demand Q108 HN67GJ002 sequencer is constructed with durable materials designed to withstand the rigors of typical HVAC operations. Its robust design features quality metal and plastic components that offer longevity. This means it can handle frequent cycling without compromising performance, thus ensuring reliability over time within your heating and cooling system. -
Question:
Is the Supplying Demand Q108 sequencer energy efficient?
Answer: Yes, the Supplying Demand Q108 HN67GJ002 sequencer is designed to enhance the energy efficiency of your heating and cooling systems. By effectively controlling when your system turns on or off based on temperature thresholds, it minimizes energy waste, leading to lower energy bills. Users can expect significant energy savings while maintaining consistent home comfort levels throughout the year. -
Question:
What are common signs that the sequencer needs replacement?
Answer: Common signs that may indicate the need for replacing the Supplying Demand Q108 HN67GJ002 sequencer include inconsistent heating or cooling cycles, unusual noise from the HVAC system, or the system failing to operate completely. If you notice that the sequencer is malfunctioning, replacing it promptly can prevent more extensive system issues and help maintain energy efficiency and comfort in your home. -
Question:
Where can I buy the Supplying Demand Q108 HN67GJ002 furnace heat pump sequencer?
Answer: You can purchase the Supplying Demand Q108 HN67GJ002 Furnace Heat Pump Sequencer from Ubuy. Ubuy is a reliable platform that offers a wide variety of HVAC products, ensuring quality and service with every purchase. With their user-friendly interface and detailed product descriptions, finding and buying this sequencer is straightforward and efficient.
Supplying Demand Heaters & Accessories Editorial Review
This relay is designed to delay the indoor fan start for heating purposes. As per the FAQ, the fan starts approximately after 15 seconds from the cold start and around 25 seconds when the thermostat temperature is reached. Overall, the product seems to work well for its intended purpose, although some customers may have received defective units that resulted in the fan turning on at unexpected times.
Customer Reviews & Ratings
-
5 Star
100%
-
4 Star
0%
-
3 Star
0%
-
2 Star
0%
-
1 Star
0%
Review this product
Share your thoughts with other customers
Pros
- Works as intended for heating purposes
- Delay time seems suitable for most customers
Cons
- Some customers received defective units
Product Price History
Important information
- Limitations : For products shipped internationally, please note that any manufacturer warranty may not be valid; manufacturer service options may not be available; product manuals, instructions, and safety warnings may not be in destination country languages; the products (and accompanying materials) may not be designed in accordance with destination country standards, specifications, and labeling requirements; and the products may not conform to destination country voltage and other electrical standards (requiring use of an adapter or converter if appropriate). The recipient is responsible for assuring that the product can be lawfully imported to the destination country. When ordering from Ubuy or its affiliates, the recipient is the importer of record and must comply with all laws and regulations of the destination country.
- Not all the products listed on Ubuy are for sale, as Ubuy is a global search engine. Products are subject to export/trade regulations.
NAD 918
Order now and get it around Sunday, June 28
This item is not restrict in my country.(Please click on above link if this item is not restrict in your country, So our team will review and allow.)
QTY:
Ubuy works hard to protect your security and privacy. Our advanced payment security system ensures confidentiality by encrypting your information during transmission using AES (Advanced Encryption Standards) and SSL (Secure Socket Layer) protocols. Your payment details are 100% secure as we do not share your payment details with third party sellers.
Features & Benefits
- Designed for electric furnaces, heat pumps, gas furnaces, and oil furnaces
- 24 Volt control circuit
- (1) Switch
- On: 1 - 25 Seconds | Off: 65-115 Seconds
- Five second delay between all subsequent stages
- Compatible with Major Brands